Toggle navigation
Home
Home
About Us
History
Vision & Values
Why Choose Us
Products
Boilers
Mobrey
Level Gauges
Gauge Glass Assembley
Level Indicators
Level Controllers
Level Transmitters
Level Switches
Forged Flanges
Valves
Value Proposition
Quality
Certifications
Clients
Contact
Home
Level Controllers
Level Controller Pneumatic
Level Controller Pneumatic
Principle of Operation:
The operation of Vincos level controller is based on Archimedes principal. In the level controller the body immersed is called a displacer which is suspended from a torsional measuring spring called torque tube. The displacement for full level range varies from zero (displacer hanging free) to 100% at the top range. The displacer always weighs more than the upward buoyant force which may be developed by the liquid in which it is submerged. Although the displacer rises and falls with level changes, its movement is substantially less than actual level movement. The difference in movement between displacer & liquid level is dependent On the cross sectional area of the displacer, the specific of the liquid and the stiffness of the torque tube. Displacer are usually of cylindrical shape, having constant cross sectional area so that for each equal increment of Submersion depth, an equal increment of buoyancy change will result, Yielding the desired linear or proportional relationship. The torque tube is designed to twist a specific amount for each increment of buoyancy change To be insensitive to pressure changes on the vessel. The degree of rotation of inner end of torque tube will be in linear relation to the degree of Buoyancy. The rotation of shift is converted to proportional pneumatic output.
Specifications:
Input Signal:
Liquid Level or Liquid-to-Liquid Interface Level from 0 to 100 Percent of Displacer Length. Standard Length for all Sensors in mm.
Liquid Density:
From 30% to 100 percent of displacement force change obtained with given displacer volume. Standard volume is 1620cm
3
.
Output Signal:
0.2-1 kg/cm
2
DIRECT: increase in level increases output.
DIRECT: increase in level decreases output.
Span:
Adjustment over 30 to 100% of standard displacer length.
Set Point: (Controller)
Continuously adjustable to position set point less than 100% of transmitter anywhere within the displacer length (liquid Or interface level or displacer force change (density).
Performance:
Accuracy transmitter only ± 1 percent of output pressure change at 100 percent span (100% P.B)
Ambient Temperatures:
55°C (for controller/transmitter)
Process Temperature:
Upto150°C
Internal Ball Float Level Controller
Level Controller Pneumatic
Microvalve Level Controller
Presure Indicating & Controller
Probe Level Controller
Controller Unit
Temperature Controller
Get in Touch
Steamgen Control Systems Welcomes your Questions, Comments and Suggestions.
Contact Info
Steamgen Control Systems Manufacturing Units
Unit: I
K-166 Cluster-K, Sector 5, DSIDC Bawana,
New Delhi -
110039
,
India
Phone:
+91-11-65572727, +91-9990972727
Unit: II
Plot No - 20, KH.31/18, Meera Enclave, Ranhoula,
New Delhi -
110041
,
India
Phone:
+91-11-65572727, +91-9990972727
Steamgen Control Systems Regional Sales Office
New Delhi:
E - 6, Harbans Bhawan - I, DDA Complex, Nangalraya,
New Delhi -
110046
,
India
Mobile:
+91-9650122727
E-Mail:
mkt@Steamgenglobal.com
Ahmedabad:
5, Devbhoomi Nagar, Part-I, D-Cabin, Sabarmati,
Ahmedabad -
380019
,
India
Mobile:
+91-7720834658
E-Mail:
mkt@Steamgenglobal.com
Contact Form
Send Message